← All CVEs

CVE-2019-14927

high · 7.5

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).

7.5
CVSS
41.8%
EPSS (exploit prob.)
99th
EPSS percentile
2019-10-28
Published

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Weaknesses

CWE-306CWE-425

Affected products

VendorProductAffected versions
mitsubishielectricsmartrtu_firmware<= 2.02
mitsubishielectricsmartrtuall versions
ineame-rtu_firmware<= 3.0
ineame-rtuall versions

Check a specific version with /api/v1/cve/match.

References

Query this programmatically:

curl https://evil-db.io/api/v1/cve/CVE-2019-14927