← All CVEs

CVE-2025-30042

critical · 9

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.

9
CVSS
0.1%
EPSS (exploit prob.)
0th
EPSS percentile
2026-03-02
Published

CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weaknesses

CWE-603

Affected products

VendorProductAffected versions
cgmclininet< 2025.ms2

Check a specific version with /api/v1/cve/match.